624BLD
Electronic control unit
Use application field
For 230V vehicle barriers
![]() |
![]() |
- It can be used together with all following barrier models: FAAC 620, 640, 642 INOX.
Model |
Item code |
---|---|
624BLD |
2022715 |
Model |
624BLD |
---|---|
Power supply voltage |
220-240V~ 50/60 Hz |
Max. power |
7 W |
Motor max power |
300 W |
Max. accessories load |
500 mA |
Accessories power supply |
24V |
Programming |
3 keys (+, -, F) and display |
Operating logic |
Automatic, Automatic 1, Semi-automatic, Parking, Parking-Automatic, Condominium, Condominium-Automatic, FAAC-CITY, Manned, Remote, Custom |
Programmable functions |
Logic, Pause time, Thrust, Loop l and 2, Torque at initial thrust, Pre-flashing, Slow Closing, Deceleration time, Work time, LED output, Failsafe output, Status output, BUS output, Service Request |
Work time |
Programmable (from 0 to 4 min) |
Pause time |
Programmable (from 0 to 4 min) |
Thrust power |
Programmable on 50 levels |
Terminal board inputs |
Loop 1, Loop 2, Open, Close,Safety in closing, Stop, Emergency, 230V~ Power supply + Earth |
Terminal board outputs |
Flashing lamp, fan, motor, 24V |
Rapid connector |
5-pin fitting for MINIDEC, DECODER or RP/RP2 receiver, Opening and closing limit switches, motor capacitor, beam release sensor |
Integrated detector 2 independent channels |
Real time self-calibration, sensitivity independent from loop geometry, loop operating frequency adjustment, message of “loop engaged” with LED display, loop status can be directed to programmable outputs, adjustment time over 2 levels. |
Protection Fuses |
F1=F 5A-250V~ F2=T 0.8A-250V~ |
Operating ambient temperature |
-20°C ÷ +55°C |
This control unit does not provide accessories because it is integrated in the operator.